PublicationDetail

Chair for Computer Aided Medical Procedures & Augmented Reality
Lehrstuhl für Informatikanwendungen in der Medizin & Augmented Reality

THIS WEBPAGE IS DEPRECATED - please visit our new website

F. Navarro, , M. Günther, , A. Gafita, M. Bieth, G. Tetteh, Jian Wang, S. Weber, M. Eiber
qPSMA: Semiautomatic Software for Whole-Body Tumor Burden Assessment in Prostate Cancer Using 68Ga-PSMA11 PET/CT
Proceedings of the Journal of Nuclear Medicine (bib)

Our aim was to introduce and validate qPSMA, a semiautomatic software package for whole-body tumor burden assessment in prostate cancer patients using 68Ga-prostate-specific membrane antigen (PSMA) 11 PET/CT. Methods: qPSMA reads hybrid PET/CT images in DICOM format. Its pipeline was written using Python and C++ languages. A bone mask based on CT and a normal-uptake mask including organs with physiologic 68Ga-PSMA11 uptake are automatically computed. An SUV threshold of 3 and a liver-based threshold are used to segment bone and soft-tissue lesions, respectively. Manual corrections can be applied using different tools. Multiple output parameters are computed, that is, PSMA ligand–positive tumor volume (PSMA-TV), PSMA ligand–positive total lesion (PSMA-TL), PSMA SUVmean, and PSMA SUVmax. Twenty 68Ga-PSMA11 PET/CT data sets were used to validate and evaluate the performance characteristics of qPSMA. Four analyses were performed: validation of the semiautomatic algorithm for liver background activity determination, assessment of intra- and interobserver variability, validation of data from qPSMA by comparison with Syngo.via, and assessment of computational time and comparison of PSMA PET–derived parameters with serum prostate-specific antigen. Results: Automatic liver background calculation resulted in a mean relative difference of 0.74% (intraclass correlation coefficient [ICC], 0.996; 95%CI, 0.989;0.998) compared with METAVOL. Intra- and interobserver variability analyses showed high agreement (all ICCs > 0.990). Quantitative output parameters were compared for 68 lesions. Paired t testing showed no significant differences between the values obtained with the 2 software packages. The ICC estimates obtained for PSMA-TV, PSMA-TL, SUVmean, and SUVmax were 1.000 (95%CI, 1.000;1.000), 1.000 (95%CI, 1.000;1.000), 0.995 (95%CI, 0.992;0.997), and 0.999 (95%CI, 0.999;1.000), respectively. The first and second reads for intraobserver variability resulted in mean computational times of 13.63 min (range, 8.22–25.45 min) and 9.27 min (range, 8.10–12.15 min), respectively (P = 0.001). Highly significant correlations were found between serum prostate-specific antigen value and both PSMA-TV (r = 0.72, P < 0.001) and PSMA-TL (r = 0.66, P = 0.002). Conclusion: Semiautomatic analyses of whole-body tumor burden in 68Ga-PSMA11 PET/CT is feasible. qPSMA is a robust software package that can help physicians quantify tumor load in heavily metastasized prostate cancer patients.
This material is presented to ensure timely dissemination of scholarly and technical work. Copyright and all rights therein are retained by authors or by other copyright holders. All persons copying this information are expected to adhere to the terms and constraints invoked by each authors copyright. In most cases, these works may not be reposted without the explicit permission of the copyright holder.



Edit | Attach | Refresh | Diffs | More | Revision r1.13 - 30 Jan 2019 - 15:16 - LeslieCasas

Lehrstuhl für Computer Aided Medical Procedures & Augmented Reality    rss.gif