Y. Genc, M. Tuceryan, N. Navab
Practical Solutions for Calibration of Optical See-Through Devices
IEEE International Symposium on Mixed and Augmented Reality (ISMAR'02), October 2002 (bib)

Registration is a crucial task in a see-through augmented reality (AR) system. The importance stems not only from the fact that registration requires careful calibration but also from the necessity that any calibration procedure should take users into account. Tuceryan et al. (2002) proposed a general method for calibrating a see-through device based on dynamic alignment of virtual and real points. Although a powerful tool, our experiments showed that users find alignment of many points overwhelming. We introduce improvements to simplify the calibration process and increase the success rate. We first identified why calibration parameters differ from user to user and how this can be prevented by adopting particular configurations for the tracker sensor and display. This allowed us to re-use the existing calibrations. Furthermore, we have introduced a simpler model for the calibration that requires fewer user inputs, typically four, to calibrate the system.
This material is presented to ensure timely dissemination of scholarly and technical work. Copyright and all rights therein are retained by authors or by other copyright holders. All persons copying this information are expected to adhere to the terms and constraints invoked by each authors copyright. In most cases, these works may not be reposted without the explicit permission of the copyright holder.



Edit | Attach | Refresh | Diffs | More | Revision r1.13 - 30 Jan 2019 - 15:16 - LeslieCasas

Lehrstuhl für Computer Aided Medical Procedures & Augmented Reality    rss.gif