M. Eiber, M. Souvatzoglou, A. Pickhard, D. Loeffelbein, A. Knopf, K. Holzapfel, A. Martinez-Möller, S. Nekolla, E. Scherer, M. Schwaiger, E. Rummeny, A. Beer
Simulation of a MR-PET protocol for staging of head-and-neck cancer including Dixon MR for attenuation correction
European Journal of Radiology 2012;81:2658-2665. (bib)

Purpose
To simulate and optimize a MR protocol for squamous cell cancer of the head and neck (HNSCC) patients for potential future use in an integrated whole-body MR-PET scanner. Materials and Methods: On a clinical 3T scanner, which is the basis for a recently introduced fully integrated whole-body MR-PET, 20 patients with untreated HNSCC routinely staged with 18F-FDG PET/CT underwent a dedicated MR protocol for the neck. Moreover, a whole-body Dixon MR-sequence was applied, which is used for attenuation correction on a recently introduced hybrid MR-PET scanner. In a subset of patients volume-interpolated-breathhold (VIBE) T1w-sequences for lungs and liver were added. Total imaging time was analyzed for both groups. The quality of the delineation of the primary tumor (scale 0-3) and the presence or absence of lymph node metastases (scale 1-5) was evaluated for CT, MR, PET/CT and a combination of MR and PET to ensure that the MR-PET fusion does not cause a loss of diagnostic capability. PET was used to identify distant metastases. The PET dataset for simulated MR/PET was based on a segmentation of the CT data into 4 classes according to the approach of the Dixon MR-sequence for MR-PET. Standard of reference was histopathology in 19 cases. In one case no histopathological confirmation of a primary tumor could be achieved. Results: Mean imaging time was 35:17min (range: 31:08-42:42min) for the protocol including sequences for local staging and attenuation correction and 44:17min (range: 35:44-54:58) for the extended protocol. Although not statistically significant a combination of MR and PET performed better in the delineation of the primary tumor (mean 2.20) compared to CT (mean 1.40), MR (1.95) and PET/CT (2.15) especially in patients with dental implants. PET/CT and combining MR and PET performed slightly better than CT and MR for the assessment of lymph node metastases. Two patients with distant metastases were only identified by PET. Conclusion: We established a potential MR-protocol to be used for HNSCC patients in a recently introduced MR-PET scanner. The proposed protocol can be performed in an acceptable time frame and did not lead to a loss of diagnostic capability compared to PET/CT.
This material is presented to ensure timely dissemination of scholarly and technical work. Copyright and all rights therein are retained by authors or by other copyright holders. All persons copying this information are expected to adhere to the terms and constraints invoked by each authors copyright. In most cases, these works may not be reposted without the explicit permission of the copyright holder.



Edit | Attach | Refresh | Diffs | More | Revision r1.13 - 30 Jan 2019 - 15:16 - LeslieCasas

Lehrstuhl für Computer Aided Medical Procedures & Augmented Reality    rss.gif