PublicationDetail

Chair for Computer Aided Medical Procedures & Augmented Reality
Lehrstuhl für Informatikanwendungen in der Medizin & Augmented Reality

THIS WEBPAGE IS DEPRECATED - please visit our new website

G. Zahnd, M. Orkisz, A. Sérusclat, P. Moulin, D. Vray
Evaluation of a Kalman-based block matching method to assess the bi-dimensional motion of the carotid artery wall in B-mode ultrasound sequences
Medical Image Analysis (bib)

We aim at investigating arterial diseases at early stage, by assessing the longitudinal (i.e. in the same direction as the blood flow) motion of the intima-media complex. This recently evidenced phenomenon has been shown to provide relevant and complementary information about vascular health. Our method assesses the longitudinal and radial motion from clinical in vivo B-mode ultrasound sequences. To estimate the trajectory of a selected point during the cardiac cycle, we introduce a block matching method that involves a temporal update of the reference block using a pixel-wise Kalman filter. The filter uses the initial gray-level of the pixel as control signal to avoid divergence due to cumulating errors. The block and search-window sizes are adapted to the tissue of interest. The method was evaluated on image sequences of the common carotid artery, acquired in 57 healthy volunteers and in 25 patients at high cardiovascular risk. Reference trajectories were generated for each sequence by averaging the tracings performed by three observers. Six different computerized techniques were also compared to our method. With a pixel size of 30 µm, the average absolute motion estimation errors were 84±107 µm and 20±19 µm for the longitudinal and radial directions, respectively. This accuracy was of the same order of magnitude as the inter- and intra-observers variability, and smaller than for the other methods. The estimated longitudinal motion amplitude was significantly reduced in at-risk patients compared with healthy volunteers (408±281 µm vs 643±274 µm, p<0.0001). Our method can constitute a reliable and time-saving technique to investigate the arterial stiffness in clinical studies, in the objective to detect early-stage atherosclerosis.
This material is presented to ensure timely dissemination of scholarly and technical work. Copyright and all rights therein are retained by authors or by other copyright holders. All persons copying this information are expected to adhere to the terms and constraints invoked by each authors copyright. In most cases, these works may not be reposted without the explicit permission of the copyright holder.



Edit | Attach | Refresh | Diffs | More | Revision r1.13 - 30 Jan 2019 - 15:16 - LeslieCasas

Lehrstuhl für Computer Aided Medical Procedures & Augmented Reality    rss.gif