R. Feurer, C. Hennersperger, J.B. Runyan, C.F. Seifert, J. Pongratz, M. Wilhelm, J. Pelisek, N. Navab, E. Bartels, H. Poppert
Reliability of a freehand three-dimensional ultrasonic device allowing anatomical orientation “at a glance”: Study protocol for 3D measurements with Curefab CS® Journal of Biomedical Graphics and Computing, Vol. 2:2 (bib) |
||
Background and Purpose: 3D ultrasonic measurement of carotid atherosclerotic lesions has emerged as an important tool for research and patient management. We sought to evaluate the accuracy and the reliability of a new easy-to-use magnetically tracked freehand 3D ultrasonic device with quick reconstruction time, allowing for anatomical orientation “at a glance” for calibration and distance measurements, with unique usability as a combined tool for image acquisition, registration and measurement within 3-D ultrasonic (US) volumes, which is furthermore connectable to every conventional US-machine. To enable a complete evaluation of the whole system, three different key points had to be addressed: the reproducibility of the calibration procedure, the absolute accuracy of the whole system and a direct comparison to CT and MRI imaging modalities. Materials and Methods: For validating our calibration method, a set of 6 calibrations was performed; each consisting of 6 records of a pyramid phantom taken from different positions and angles. To evaluate the accuracy of the whole 3D-ultrasound system, the point reconstruction accuracy and the distance accuracy were determined in a point phantom made out of a single metal wire vertically attached to the bottom of a plastic tub filled with water. For distance measurements, a precisely manufactured plastic tube phantom was scanned and the length between fixed landmarks on the tube was measured. In a final step, 3D US records acquired with Curefab CS were compared to CT and MRI scans; for this purpose all ultrasonic data was manually registered to the CT/MRI data. Results: Concerning calibration precision the tested Curefab CS system performs state of the art compared to reviews of recent freehand 3D-Ultrasound calibration methods. The point reconstruction measure for evaluation of system accuracy retrieved a mean point accuracy of 1.52 mm in contrast to values ranging from 1.67 to 3.63 mm. Mean total error of distance measurements was 0.9% with standard deviation 0.56% in our study, compared with values reaching from about 1% up to 2.3% in other studies on this subject. All quantitative measurement results are listed in a summarized form in Table 1. Besides quantitative evaluation, 3D-ultrasound records acquired with the Curefab CS system were also compared to CT and MRI scans of patients (see Figure 3 and Figure 4). The alignment of both image modalities showed promising results for future development of diagnostic tools using all image data. Discussion and Conclusion: Our study demonstrates that 3D measurements with Curefab CS are feasible with satisfactory reliability and accuracy. From the results gathered in our study we conclude that 3D-imaging with Curefab CS might start off the possibility of accurate visualization, volume measurement, carotid plaque characterization and identification of vulnerable plaques in the very near future. | ||
This material is presented to ensure timely dissemination of scholarly and technical work. Copyright and all rights therein are retained by authors or by other copyright holders. All persons copying this information are expected to adhere to the terms and constraints invoked by each authors copyright. In most cases, these works may not be reposted without the explicit permission of the copyright holder. |